Specifications
for Thermocouples
Sheath
Appearance:
Metallic, 32 micro inch rms finish or smoother
Tolerance:
O.D. is within = 15% or = .002" of nominal,
Whichever is larger
Anneal:
Sheath shall be fully annealed
Pressure
Can withstand an external
pressure equivalent to 50,000 PSI (2500 kg/cm )
Fabrication
Can be welded, brazed,
or soldered without changing insulation resistance
providing normal care is used for the metals
and thickness involved
Insulation
Standard Composition:
Compacted MgO
Insulation
Resistance
Room Temperature
Minimum of 100 Mega ohms at 600 VDC
(For d=0.062 and greater)
Minimum of 100 Mega ohms at 50 VDC
(For d=less than 0.062)
At 1800°F
Minimum of 20,000 ohm-ft at 6 VDC
|