LevelAc's Model SL-100
Series level switches are designed for top mounting
in open tanks or closed vessels where top access
for float clearance is available. Installation
is by means of a 1" NPT connection, Insertion
depth should be limited to 132".
|

|
Mercury Switching Station -
A glass capsule
containing the mercury and switch
contacts is mounted on a pivoted arm.
A magnetic armature moves up and down
inside a non-magnetic sealing tube
following movement of the float caused
by changing liquid level in the float
chamber. As the armature enters the
field of the Alnico V magnet mounted
on the opposite end of the pivoted
arm, magnetic attraction causes the
magnet to approach the sealing tube
and tilt the mercury capsule to make
or break an electrical circuit.
Snap Switching
Stations - An
Alnico 8 magnet surrounds the sealing
tube and concentrates powerful magnetic
force in a small space. Movement of
the armature into the magnetic field
shunts attraction away from the external
pole pieces which allows the pivoted
actuator plate to "snap"
the SPDT switch making the circuit
"COM" to "NC"
and breaking "COM" to "NO".
Interface
Operation - To
control the dividing line (interface)
between two immiscible liquids of
different specific gravities, the
float is precisely loaded to sink
in the lighter liquid above but be
supported on the surface of the heavier
liquid below. Float loading is based
on the minimum specific gravity difference
between the two liquids (highest sp.
G of the lighter liquid and lowest
sp. G. of the heavier liquid) at the
operating temperature. For LevelAc's
intended for interface service, complete
information on specific gravities
of both liquids must be furnished. |
|
 |
Switch
Stations:
 |
| Number: |
One
or two. |
|
 |
 |
| Mercury
Type: |
Equiped
with one or two
SPDT mercury switches.
|
| Switch
Characteristics: |
Hermetically
sealed.
SPDT mercury switches
are standard.
|
|
| RATINGS |
| Volts |
AC |
DC |
| Amps* |
H.P. |
Pilot
Duty |
Amps* |
H.P. |
| 120 |
13 |
1/2 |
345
VA |
10 |
1/2 |
| 240 |
6.5 |
1 |
345
VA |
5 |
1/2 |
| 440 |
3 |
1 |
345
VA |
- |
- |
. |
 |
 |
| Snap
Type: |
Equipped
with one or
two SIPDT electrical snap
switches or one pneumatic
switch.
|
|
 |
Electric
Switch Characteristics:
Non-mercury SPDT snap-acting
type. Fully enclosed in
high-strength plastic.
|
|
| |
Rating
15 amps @ 120 or 240 VAC
1/2 amp @ 120 VDC
1/4 amp @ 240 VDC
Pilot duty --- 345 VA
|
 |
Pneumatic
Switch characteristics:
A pneumatic valve with ball
seating for tight closing and
designed for mounting on a snap
switching station. Snap-action
of the switch station produces
"on/off'" or "closed/vent"
operation. May be mounted to
vent on high level or low level,
Only one pneumatic switch per
station may be installed. |
 |
 |
| Rating
|
0
to 60 psi max. |
|
| AIR
VENTING CAPACITY |
| PSI |
9 |
15 |
20 |
30 |
40 |
50 |
60 |
| SCFM |
.63 |
.84 |
.99 |
1.29 |
1.58 |
1.86 |
2.16 |
|
|
 |
Switching
Differential (See Fig 1) :
 |
| One
Station |
Adjustable
l/2" to 3½",
Factory set at 11/2"
unless otherwise specified.
|
|
| |
 |
| Two
Station |
Adjustable
- Adjusting nut spacing
is factory set for minimum
differential. Spacing
between stations is set
at 3" maximum, This
center-to-center spacing
is adjustable. |
 |
Snap Stations |
2"
min. to 3"
max. |
Mercury Stations |
1
1/16" min.
to 3" max. |
|
|
 |
Finish
 |
| Switch
Housing |
Blue
polyurethane |

|
A - Station Differential
(Lower)
B - Series Differential
C - High - Low
Differential
D - Station Differential
(Upper)
H - Maximum Insertion
Depth. |
| Applicable
Dimensions must be specified
on order. |
| NOTE:
Dimension "H"
is the distance from the
upper limit of differential
"A" to the bottom
of the mounting nut. As
noted, differential "A"
refers to the lower station
when two switch stations
are installed. |
|
|
|
|
|